● D7500 Bus Host: big screen the Chinese blue screen display with 8 wired zones and 248 bus zone. ● 8 partitions: D7500 series can be divided into eight fully independent partitions, each partition can be its own separate keyboard and TD report code. Event memory (black box): the system up with 400 historical events, to save the time and date on the keyboard, such as arm / disarm, alarm. Keyboard programming: This system entirely by keyboard programming without the expensive hand-held programmer. 200 user codes: the system can be 200 four-digit user code, except a super user code and other user codes can be divided into six different permission levels can be used next to Road test, and the system is disarmed. ● Auto Open / Close Delay arm: time can be made available for daily automatic arming each partition. ● public partitions: a partition can be programmed to follow some or all of the other the arming state. ● Forced Arming: The system can be based on some variety of deployment settings can be programmed, automatic bypass a group of zones after arming answering machine priority. Flexible digital communication: communicating hosts currently used by most alarm receiver support 4 +2 the contact ID digital communications format. ● The host also has an alarm output function, anti-take over the protection of ...
|
Input power |
AC18V 50W 50HZ/60HZ |
Alarm output port |
DC12V 1.75A |
Standby power |
250 |
Power supply |
12V, 7AH maintenance-free battery |
Auxiliary output power |
DC12V, 1.0A Max |
Alarm state current |
250mA |
Motherboard power consumption |
Static 175Ma |
Programmable port output |
2 |
Dimensions |
365 * 310 * 85mm |
|
|
|
|
|